Evolution Sensors and Controls, LLC - 6700 Forum Drive Suite 125 - Orlando, FL 32821 - Ph. 407-420-8080 - Fax: 407-420-8083 - email: info@evosensors.com
Grounded Thermocouple Probes - Items tagged as "Cass-116g-12-pfa"
A Grounded ThermocoupleProbe has the thermocouple juction in firm Contact with the Inside Tip of the metal tube, sheath or mounted housing. Typically the 2 thermocouple wires forming the juction are welded to or part of the inside tip
Fast Thermalresponse and provides protection of thermocouple junction from servere temperature measurement environments
Grounded thermocouples are a very popular design although they can experience Electromagnetic Interference (EMI) from motors, power supplies and other devices resulting in temperature measurement errors.
The metal sheath can be a potential antenna or conductor.
The temperature signal generated is a very small milivolt signal and is more susceptible to interference than a miliamp or other signal output.
If Electrical Interference is an potential issue in your temperature measurement application potential solutions include an ungrounded thermocouple juction design, a grounding wire connected the metal probe sheath, twisted shielded thermocouple lead wire, a RTD temperature sensor and other potentials solutions.